MR-US2K / US2KA (Tower UPS)

Protect Your Data and Devices

Output: 2kVA / 2kW


  • Single Phase On-Line UPS

    1kVA / 2kVA / 3kVA

     

  • • High-Frequency Double Conversion Online with DSP Control
    • Up to 95.5% High Efficiency for Energy Conservation
    • Supply Utility Power in the Event of Overload or Fault
    • Enhanced Application Availability
    • Real-time Notification of Power Conditions
    • Temporary Battery Power During Outages
    • Intuitive Control Panel for Quick Status Understanding
    • Management via Serial Interface Ports
    • Support for Economic Operation Mode
    • High Output Power Factor at 1.0PF
    • Easy Recovery from Overloads
    • Automatic Self-Test
    • Intelligent Battery Management
    • Wide Input Voltage Range

Leave a message

隐藏域元素占位

  • Overview
  • Specifications
  • Downloads
  • Support
  • 概要
  • Single Phase On-Line UPS

    1kVA / 2kVA / 3kVA

     

Expand All

On-Line UPS(Tower Type) 1k-10kVA (220V) Part 1
Model MR-US1K MR-US2K MR-US3K MR-US6K MR-US10K
Rated Capacity 1kVA / 1kW 2kVA / 2kW 3kVA / 3kW 6kVA / 6kW 10kVA / 10kW
Output
Output Voltage 208 / 220 / 230 / 240VAC
Output Frequency

50 / 60Hz ± 0.1 %

Output Harmonic Distortion ≤3% THD(linear load), ≤5% THD(non-linear load)
Output Power Factor 1.0
Switching Time AC Mode to Battery Mode 0ms, Inverter to Bypass 4ms(Typical)
UPS Type Double-conversion On-Line
Waveform Type Pure Sine wave
Input
Rated Input Voltage 208 / 220 / 230 / 240VAC
Input Voltage Range 110 – 300VAC, 110 – 176VAC, 280 – 300VAC (power limited)
Input Frequency 50 / 60 ± 6Hz (Default), ±10Hz (Adjustable)
Input Power Factor ≥0.99
Load Efficiency
AC Mode Full load 94.5%@220VAC Full load 95.5%@220VAC Full load 95.5%@220VAC Full load effciency 95%, Maximum efficiency 95.5%
Battery Mode Full load 89.5%@36VDC Full load 91.5%@72VDC Full load 91.5%@96VDC Full load effciency 94.8% (20pcs batteries), Maximum efficiency 95.3%

 

On-Line UPS(Tower Type) 1k-10kVA (220V) Part 2
Battery
Battery Type Lead-acid battery
Battery Voltage

12V/7Ah ( 9Ah optional)*2

12V/7Ah ( 9Ah optional)*4

12V/7Ah ( 9Ah optional)*6

12V / 7Ah (9Ah optional)*16
Typical Recharge Time 4 – 5 hours recover to 90% capacity 7 – 9 hours recover to 90% capacity
Charging Current Default 1A (No settable)
Physical
Form Factor Tower
Dimension,D*W*H(mm) 276 * 145 * 225 392 * 145 * 225  395 * 190 * 325 460 * 190 * 615
Net Weight(kg) 8.6 14.3 20.5 50.6 50.8
Communication Interface RS232, USB, EPO, Smart Card Slot RS232, USB, EPO, SNMP, Dry-contact (Optional), Maintenance Connector (Optional)
Communications & Management
Control Panel Multifunction LCD status and control console
Alarm Alarm every 8 seconds in battery mode
Alarm for low battery every second
Alarm on overload every second
Protection Short circuit, Overload , Overcharge and Overdischarge protection
Environment
Operating Temperature 0°C – 40°C
Storage Temperature -15°C – 60°C (Battery: 0°C – 40°C)
Relative Humidity 20 – 95% (non-condensing)
Audible Noise Less than 50dB (1 meter from surface)
Standard & Approvals
Safety IEC / EN62040-1, IEC / EN60950-1
EMC IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8
On-Line UPS(Tower Type) 1k-10kVA (110V) Part 1
Model MR-US1KA MR-US2KA MR-US3KA MR-US6KA MR-US10KA
Rated Capacity 1kVA / 1kW 2kVA / 2kW 3kVA / 3kW 6kVA / 6kW 10kVA / 10kW
Output
Output Voltage 100 / 110 / 115 / 120 / 127VAC 
Output Frequency

50 / 60Hz ± 0.1 %

Output Harmonic Distortion ≤2% THD(linear load), ≤4% THD(non-linear load)
Output Power Factor 1.0
Switching Time AC Mode to Battery Mode 0ms, Inverter to Bypass 4ms(Typical)
UPS Type Double-conversion On-Line
Waveform Type Pure Sine wave
Input
Rated Input Voltage 100 / 110 / 115 / 120 / 127VAC
Input Voltage Range 110 – 300VAC, 110 – 176VAC, 280 – 300VAC (power limited)
Input Frequency 50 / 60 ± 6Hz (Default), ±10Hz (Adjustable)
Input Power Factor ≥0.99
Load Efficiency
AC Mode Full load 93.5%@110VAC Full load 94.5%@110VAC Full load 94.5%@110VAC Full load effciency 95%, Maximum efficiency 95.5%
Battery Mode Full load 90.5%@36VDC Full load 93.5%@72VDC Full load 93.5%@96VDC Full load effciency 94.8%(20pcs batteries), Maximum efficiency 95.3%

 

On-Line UPS(Tower Type) 1k-10kVA (110V) Part 2
Battery
Battery Type Lead-acid battery
Battery Voltage

12V/7Ah ( 9Ah optional)*2

12V/7Ah ( 9Ah optional)*4

12V/7Ah ( 9Ah optional)*6

12V / 7Ah (9Ah optional)*16
Typical Recharge Time 4 – 5 hours recover to 90% capacity 7 – 9 hours recover to 90% capacity
Charging Current Default 1A (No settable)
Physical
Form Factor Tower
Dimension,D*W*H(mm) 392*145*225 395*190*325 460 * 190 * 615
Net Weight(kg) 9 15.6 20.7 91.8 104.8
Communication Interface RS232, USB, EPO, Smart Card Slot RS232, USB, EPO, SNMP, Dry-contact (Optional), Maintenance Connector (Optional)
Communications & Management
Control Panel Multifunction LCD status and control console
Alarm Alarm every 8 seconds in battery mode
Alarm for low battery every second
Alarm on overload every second
Protection Short circuit, Overload , Overcharge and Overdischarge protection
Environment
Operating Temperature 0°C – 40°C
Storage Temperature -15°C – 60°C (Battery: 0°C – 40°C)
Relative Humidity 20 – 95% (non-condensing)
Audible Noise Less than 50dB (1 meter from surface)
Standard & Approvals
Safety IEC / EN62040-1, IEC / EN60950-1
EMC IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8

Support

Please contact our Tech Support department with installation, troubleshooting, or general product questions.