MR-US3K / US3KA - H (Tower UPS)

Protect Your Data and Devices

Output: 3kVA / 3kW


  • Single Phase On-Line UPS

    1kVA / 2kVA / 3kVA

     

  • ● High-Frequency Double Conversion Online with DSP Control
    ● Up to 95.5% High Efficiency for Energy Conservation
    ● Supply Utility Power in the Event of Overload or Fault
    ● Enhanced Application Availability
    ● Real-time Notification of Power Conditions
    ● Temporary Battery Power During Outages
    ● Intuitive Control Panel for Quick Status Understanding
    ● Management via Serial Interface Ports
    ● Support for Economic Operation Mode
    ● High Output Power Factor at 1.0PF
    ● Easy Recovery from Overloads
    ● Automatic Self-Test
    ● Intelligent Battery Management
    ● Wide Input Voltage Range

Leave a message

隐藏域元素占位

  • Overview
  • Specifications
  • Downloads
  • Support
  • 概要
  • Single Phase On-Line UPS

    1kVA / 2kVA / 3kVA

     

Expand All

On-line UPS 1k-10kVA - H (220V)
Model MR-US1K-H MR-US2K-H MR-US3K-H MR-US6K-H MR-US10K-H
Rated Capacity 1kVA / 1kW 2kVA / 2kW 3kVA / 3kW 6kVA / 6kW 10kVA / 10kW
Output
Output Voltage 208 / 220 / 230 / 240VAC
Output Frequency

50 / 60Hz ± 0.1 %

Output Harmonic Distortion ≤3% THD(linear load), ≤5% THD(non-linear load)
Output Power Factor 1.0
Switching Time AC Mode to Battery Mode 0ms, Inverter to Bypass 4ms(Typical)
UPS Type Double-conversion On-Line
Waveform Type Pure Sine wave
Input
Rated Input Voltage 208 / 220 / 230 / 240VAC
Input Voltage Range 110 – 300VAC, 110 – 176VAC, 280 – 300VAC (power limited)
Input Frequency 50 / 60 ± 6Hz (Default), ±10Hz (Adjustable)
Input Power Factor ≥0.99
Load Efficiency
AC Mode Full load 94.5%@220VAC Full load 95.5%@220VAC Full load 95.5%@220VAC Full load effciency 95%, Maximum efficiency 95.5%
Battery Mode Full load 89.5%@36VDC Full load 91.5%@72VDC Full load 91.5%@96VDC Full load effciency 94.8% (20pcs batteries), Maximum efficiency 95.3%

 

BATTERY - H 220V
Battery
Battery Type Lead-acid battery
Battery Voltage 36V 72V 96V 192V, 240V (optional)
Physical
Form Factor Tower
Dimension,D*W*H(mm) 276 * 145 * 225 392 * 145 * 225  395* 190 * 325
Net Weight(kg) 4.7 7.0 7.5 8.8 9.6
Communication Interface RS232, USB, EPO RS232, USB, EPO, SNMP, Dry-contact, Maintenance Connector
Communications & Management
Control Panel Multifunction LCD status and control console
Alarm Alarm every 8 seconds in battery mode
Alarm for low battery every second
Alarm on overload every second
Protection Short circuit, Overload , Overcharge and Overdischarge protection
Environment
Operating Temperature 0°C – 40°C
Storage Temperature -15°C – 60°C (Battery: 0°C – 40°C)
Relative Humidity 20 – 95% (non-condensing)
Audible Noise Less than 50dB (1 meter from surface)
Standard & Approvals
Safety IEC / EN62040-1, IEC / EN60950-1
EMC IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8

  Specifications are subject to change without notice, and all product drawings are for reference only. Consult MARSRIVA for the latest design and specifications.

 

 

On-line UPS 1k-10kVA - H (110V)
Model MR-US1KA-H MR-US2KA-H MR-US3KA-H MR-US6KA-H MR-US10KA-H
Rated Capacity 1kVA / 1kW 2kVA / 2kW 3kVA / 3kW 6kVA / 6kW 10kVA / 10kW
Output
Output Voltage 100 / 110 / 115 / 120 / 127VAC 104 / 110 / 115 / 120VAC or 208 / 220 / 230 / 240VAC
Output Frequency 50 / 60Hz ± 0.1 %
Output Harmonic Distortion ≤2% THD(linear load), ≤4% THD(non-linear load) ≤2% THD(linear load), ≤5% THD(non-linear load)
Output Power Factor 1.0
Switching Time AC Mode to Battery Mode 0ms, Inverter to Bypass 4ms(Typical) 0ms.ECO Mode to Battery Mode 2ms
UPS Type Double-conversion On-Line
Waveform Type Pure Sine wave
Input
Rated Input Voltage 100 / 110 / 115 / 120 / 127VAC 208 / 220 / 230 / 240VAC
Input Voltage Range 55 – 150VAC, 55 – 85VAC and 140 – 150VAC (power limited) 110 – 300VAC, 110 – 176VAC, 276 – 300VAC (power limited
Input Frequency 50 / 60 ± 6Hz (Default), ±10Hz (Adjustable)
Input Power Factor ≥0.99
Load Efficiency
AC Mode Full load 93.5%@110VAC Full load 94.5%@110VAC Full load 94.5%@110VAC Full load effciency 95%, Maximum efficiency 95.5%
Battery Mode Full load 90.5%@36VDC Full load 93.5%@72VDC Full load 93.5%@96VDC Full load effciency 94.8% (20pcs batteries), Maximum efficiency 95.3%

 

BATTERY - H 110V
Battery
Battery Type Lead-acid battery
Battery Voltage 36V 72V 96V 192V, 240V (optional)
Charging Current 5A 5A
Physical
Form Factor Tower
Dimension,D*W*H(mm) 392*145*225 395*190*325 395 * 190 * 325
Net Weight(kg) 5 7 7.5 8.9 10
Communication Interface RS232, USB, EPO RS232, USB, EPO, SNMP, Dry-contact, Maintenance Connector
Communications & Management
Control Panel Multifunction LCD status and control console
Alarm Alarm every 8 seconds in battery mode
Alarm for low battery every second
Alarm on overload every second
Protection Short circuit, Overload , Overcharge and Overdischarge protection
Environment
Operating Temperature 0°C – 40°C
Storage Temperature -15°C – 60°C (Battery: 0°C – 40°C)
Relative Humidity 20 – 95% (non-condensing)
Audible Noise Less than 50dB (1 meter from surface)
Standard & Approvals
Safety IEC / EN62040-1, IEC / EN60950-1
EMC IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8

  Specifications are subject to change without notice, and all product drawings are for reference only. Consult MARSRIVA for the latest design and specifications.

 

 

Support

Please contact our Tech Support department with installation, troubleshooting, or general product questions.

Hours of operation: Monday – Friday 9 : 00am – 9 : 00pm UTC+8

Our Technical Support team will be happy help you with technical questions during business hours. 

Contact Tech Support: Submit Ticket Now


Submit a Support Ticket
Submit a message