MR-US3K / US3KA - H (Tower UPS)
Protect Your Data and Devices
Output: 3kVA / 3kW
-

Single Phase On-Line UPS
1kVA / 2kVA / 3kVA
-
• High-Frequency Double Conversion Online with DSP Control
• Up to 95.5% High Efficiency for Energy Conservation
• Supply Utility Power in the Event of Overload or Fault
• Enhanced Application Availability
• Real-time Notification of Power Conditions
• Temporary Battery Power During Outages
• Intuitive Control Panel for Quick Status Understanding
• Management via Serial Interface Ports
• Support for Economic Operation Mode
• High Output Power Factor at 1.0PF
• Easy Recovery from Overloads
• Automatic Self-Test
• Intelligent Battery Management
• Wide Input Voltage Range
隐藏域元素占位
- Overview
- Specifications
- Downloads
- Support
- 概要
-

Single Phase On-Line UPS
1kVA / 2kVA / 3kVA
Expand All
| Model | MR-US1KA-H | MR-US2KA-H | MR-US3KA-H | MR-US6KA-H | MR-US10KA-H | ||||||||
| Rated Capacity | 1kVA / 1kW | 2kVA / 2kW | 3kVA / 3kW | 6kVA / 6kW | 10kVA / 10kW | ||||||||
| Output | |||||||||||||
| Output Voltage | 100 / 110 / 115 / 120 / 127VAC | 104 / 110 / 115 / 120VAC or 208 / 220 / 230 / 240VAC | |||||||||||
| Output Frequency | 50 / 60Hz ± 0.1 % | ||||||||||||
| Output Harmonic Distortion | ≤2% THD(linear load), ≤4% THD(non-linear load) | ≤2% THD(linear load), ≤5% THD(non-linear load) | |||||||||||
| Output Power Factor | 1.0 | ||||||||||||
| Switching Time | AC Mode to Battery Mode 0ms, Inverter to Bypass 4ms(Typical) | 0ms.ECO Mode to Battery Mode 2ms | |||||||||||
| UPS Type | Double-conversion On-Line | ||||||||||||
| Waveform Type | Pure Sine wave | ||||||||||||
| Input | |||||||||||||
| Rated Input Voltage | 100 / 110 / 115 / 120 / 127VAC | 208 / 220 / 230 / 240VAC | |||||||||||
| Input Voltage Range | 55 – 150VAC, 55 – 85VAC and 140 – 150VAC (power limited) | 110 – 300VAC, 110 – 176VAC, 276 – 300VAC (power limited | |||||||||||
| Input Frequency | 50 / 60 ± 6Hz (Default), ±10Hz (Adjustable) | ||||||||||||
| Input Power Factor | ≥0.99 | ||||||||||||
| Load Efficiency | |||||||||||||
| AC Mode | Full load 93.5%@110VAC | Full load 94.5%@110VAC | Full load 94.5%@110VAC | Full load effciency 95%, Maximum efficiency 95.5% | |||||||||
| Battery Mode | Full load 90.5%@36VDC | Full load 93.5%@72VDC | Full load 93.5%@96VDC | Full load effciency 94.8% (20pcs batteries), Maximum efficiency 95.3% | |||||||||
| Battery | |||||||||||||
| Battery Type | Lead-acid battery | ||||||||||||
| Battery Voltage | 36V | 72V | 96V | 192V, 240V (optional) | |||||||||
| Charging Current | 5.0A (Default) | 1-12A (Settable) | |||||||||||
| Physical | |||||||||||||
| Form Factor | Rack Type | ||||||||||||
| Dimension (W*H*D) | 438mm * 88mm * 385mm | ||||||||||||
| Net Weight | 5.8kg | 7.0kg | 7.4kg | 8.7kg | 9.5kg | ||||||||
| Communication Interface | RS232, USB, EPO, Smart Card Slot | RS232, USB, EPO, SNMP, Dry-contact (optional), Maintenance Connector (optional) | |||||||||||
| Communications & Management | |||||||||||||
| Control Panel | Multifunction LCD status and control console | ||||||||||||
| Alarm | Alarm every 8 seconds in battery mode | ||||||||||||
| Alarm for low battery every second | |||||||||||||
| Alarm on overload every second | |||||||||||||
| Protection | Short circuit, Overload , Overcharge and Overdischarge protection | ||||||||||||
| Environment | |||||||||||||
| Operating Temperature | 0°C – 40°C | ||||||||||||
| Storage Temperature | -15°C – 60°C (Battery: 0°C – 40°C) | ||||||||||||
| Relative Humidity | 20 – 95% (non-condensing) | ||||||||||||
| Audible Noise | Less than 50dB (1 meter from surface) | ||||||||||||