undefined
undefined
undefined
undefined
undefined
undefined
undefined
undefined
  • undefined
  • undefined
  • undefined
  • undefined
  • undefined
  • undefined
  • undefined
  • undefined

MR-US1KRT-TIE / US1KRT / US1KART(Rack UPS)

Protect Your Data and Devices

Output: 1kVA / 1kW


  • Single Phase On-Line UPS

    1kVA / 1kW
  • • High-Frequency Double Conversion Online with DSP Control
    • Up to 95.5% High Efficiency for Energy Conservation
    • Supply Utility Power in the Event of Overload or Fault
    • Enhanced Application Availability
    • Real-time Notification of Power Conditions
    • Temporary Battery Power During Outages
    • Intuitive Control Panel for Quick Status Understanding
    • Management via Serial Interface Ports
    • Support for Economic Operation Mode
    • High Output Power Factor at 1.0PF
    • Easy Recovery from Overloads
    • Automatic Self-Test
    • Intelligent Battery Management
    • Wide Input Voltage Range

Leave a message

隐藏域元素占位

  • Overview
  • Specifications
  • Downloads
  • Support
  • 概要
  • Single Phase On-Line UPS

    1kVA / 1kW

Expand All

On-Line UPS(Rack Type) 1kVA-3kVA (220V)
Model MR-US1KRT-TIRE/US1KRT MR-US2KRT-TIRE/US2KRT MR-US3KRT-TIRE/US3KRT
Rated Capacity 1kVA / 1kW 2kVA / 2kW 3kVA / 3kW
Output
Output Voltage 208 / 220 / 230 / 240VAC
Output Frequency

50 / 60Hz ± 0.1 %

Output Harmonic Distortion ≤3% THD (linear load), ≤5% THD (non-linear load)
Output Power Factor 1.0
Switching Time AC Mode to Battery Mode 0ms, Inverter to Bypass 4ms(Typical)
UPS Type Double-conversion On-Line
Waveform Type Pure Sine wave
Input
Rated Input Voltage 208 / 220 / 230 / 240VAC
Input Voltage Range 110 – 300VAC, 110 – 176VAC, 280 – 300VAC (power limited)
Input Frequency 50 / 60 ± 6Hz (Default), ±10Hz (Adjustable)
Input Power Factor ≥0.99
Load Efficiency
AC Mode Full load 94.5%@220VAC Full load 95.5%@220VAC Full load 95.5%@220VAC
Battery Mode Full load 89.5%@36VDC Full load 91.5%@72VDC Full load 91.5%@96VDC
Battery      
Battery Type   Lead-acid battery  
Battery Quantity 2*12V/9Ah (7Ah optional) 4* 12V/9Ah (7Ah optional) 6*12V/9Ah (7Ah optional)
Charging Current   Default 1A (No settable)  
Typical Recharge Time   4 – 5 hours recover to 90% capacity  
Physical      
Form Factor   Rack Type  
Dimension,D*W*H(mm) 438 * 88 * 385 438 * 88 * 505 438 * 88 * 505
Net Weight(kg) 9.5 14.6 20.2
Communication Interface   RS232, USB, EPO, Smart Card Slot  
Environment      
Operating Temperature   0°C – 40°C  
Storage Temperature   -15°C – 60°C (Battery: 0°C – 40°C)  
Relative Humidity   20 – 95% (non-condensing)  
Audible Noise   Less than 50dB (1 meter from surface)  
Standard & Approvals      
Safety IEC / EN62040-1, IEC / EN60950-1
EMC IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8

 

On-Line UPS(Rack Type) 1kVA-3kVA (110V)
Model MR-US1KART MR-US2KART MR-US3KART
Rated Capacity 1kVA / 1kW 2kVA / 2kW 3kVA / 3kW
Output
Output Voltage 100 / 110 / 115 / 120 / 127VAC 
Output Frequency

50 / 60Hz ± 0.1 %

Output Harmonic Distortion ≤2% THD(linear load), ≤4% THD(non-linear load)
Output Power Factor 1.0
Switching Time AC Mode to Battery Mode 0ms, Inverter to Bypass 4ms(Typical)
UPS Type Double-conversion On-Line
Waveform Type Pure Sine wave
Input
Rated Input Voltage 100 / 110 / 115 / 120 / 127VAC
Input Voltage Range 110 – 300VAC, 110 – 176VAC, 280 – 300VAC (power limited)
Input Frequency 50 / 60 ± 6Hz (Default), ±10Hz (Adjustable)
Input Power Factor ≥0.99
Load Efficiency
AC Mode Full load 93.5%@110VAC Full load 94.5%@110VAC Full load 94.5%@110VAC
Battery Mode Full load 90.5%@36VDC Full load 93.5%@72VDC Full load 93.5%@96VDC
Battery      
Battery Type   Lead-acid battery  
Battery Quantity 2*12V/9Ah (7Ah optional) 4* 12V/9Ah (7Ah optional) 6*12V/9Ah (7Ah optional)
Charging Current   Default 1A (No settable)  
Typical Recharge Time   4 – 5 hours recover to 90% capacity  
Physical      
Form Factor   Rack Type  
Dimension,D*W*H(mm) 438 * 88 * 385 438 * 88 * 505 438 * 88 * 505
Net Weight(kg) 10.6 17.5 21.9
Communication Interface   RS232, USB, EPO, Smart Card Slot  
Environment      
Operating Temperature   0°C – 40°C  
Storage Temperature   -15°C – 60°C (Battery: 0°C – 40°C)  
Relative Humidity   20 – 95% (non-condensing)  
Audible Noise   Less than 50dB (1 meter from surface)  
Standard & Approvals      
Safety IEC / EN62040-1, IEC / EN60950-1
EMC IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8

 

Support

Please contact our Tech Support department with installation, troubleshooting, or general product questions.

Hours of operation: Monday – Friday 9 : 00am – 9 : 00pm UTC+8

Our Technical Support team will be happy help you with technical questions during business hours. 

Contact Tech Support: Submit Ticket Now


Submit a Support Ticket

Global

English

Submit a message